In the Electrical Harness
Installation workbench, click Light Protective Covering
in the Internal Protection toolbar.
For information on Tape Parameters, see About
Protective Coverings.
The Light Protective Covering
dialog box appears: |
 |
-
Select the catalog then the Protective covering you want
to instantiate.
-
In the specification tree, select one or more bundle
segments to be covered with the protective covering.
 |
- In case of multi-selection, the bundle segments must belong to the
same branch.
You can select normal bundle segments, as long as
they are contiguous.
- Light Protective Covering is a feature of a multi-branchable
document, and it covers bundle segments in one branch only.
|
The Protective Covering
Information is updated in the dialog box, and the protective
covering start and end points are displayed in the geometry. |
 |
-
Drag the Start Extremity or
End Extremity label to modify the location of
the internal protection.
 |
- The End Extremity here is modified.
- The protective covering turns to red informing you that it
needs to be updated.
- The protection extremity is editable all along the branch.
|
- You can also double-click any one extremity to re-limit the protective
covering.
- The Define Extremity dialog box appears:
 It lets you define the new position for the extremity from the
reference point.
- Enter 30 mm in the Distance field.
- Click Invert to invert the position of the
protection extremity to the other side of the reference point while
maintaining the same distance from the reference point.
|
-
The light protective covering is added as a separate feature to the
specification tree under the multi-branchable feature:

|