You can give your bundle segments a more realistic
behavior that reflects bundle segment stiffness when designing your harness
from scratch as well as when
updating an existing design.
This is done using the FLEX algorithm. Based on bundle segment
properties (length, diameter, etc.), CATIA computes the effective Young
modulus and other input needed by the algorithm (cross section shape,
flexibility). The algorithm takes into account protective coverings,
internal splices as well
as wires and wire groups:
- If no wires nor wire groups are routed, bundle segment stiffness is
based on individual bundle segment flexibility
- If wires and wire groups are routed, bundle segment stiffness is
based on the properties of the wires and wire groups. In this case,
individual bundle segment flexibility is ignored.
If no FLEX solution can be found, a message informs the user and the
standard algorithm is used.
The electrical designer can take advantage of all the benefits of the
FLEX algorithm while working in exactly the same way as with the standard
algorithm.
 |
Legend:
- standard algorithm: yellow
- FLEX algorithm: blue
|
Protective coverings add stiffness. This is
taken into account by the FLEX algorithm. |
Standard algorithm: |
FLEX algorithm: |
 |
 |
|
|
Internal splices add
stiffness. The FLEX algorithm takes into account the values for the
length and equivalent thickness attributes entered when defining
splices in Electrical Library.
Notes:
-
There is no visual change to the representation of the internal
splice.
- You will need to recompute all
bundle segments to take into account modifications to length
and equivalent thickness of reference internal splices, and if you
replace an internal splice by another.
|
|
 |
These functionalities require a FLEX Physical
Simulation license.
For more information on this product, see
Flex Physical Simulation Overview. |
 |
These functionalities are accessed by setting the
bundle segment computation mode to FLEX algorithm and
adjusting the balance slider. |
Designing from Scratch
|
 |
-
Set the
bundle segment computation mode to FLEX algorithm and
adjust the balance slider.
-
Select the Work with one multi-branchable per
geometrical bundle option under Tools > Options > Equipments & Systems > Electrical
Harness Discipline > Electrical Harness Installation > Harness
Management tab
-
Create a geometrical bundle.
-
Click Multi-Branchable Document
and set branch parameters in the dialog box that opens.
The Electrical Harness Assembly workbench switches
to the Electrical Harness Installation workbench. The Branch
Definition dialog box opens.

For information on standard options in the dialog box, see
Creating a New Multi-Branchable Document
and First Branch. |
 |
Note that the final slack, length and bend values
may not exactly correspond to the user input due to the fact that
the FLEX algorithm is a finite-element algorithm. If
this is the case, it can be seen when you change the build mode.
Computing the length of bundle segments in Bend or Slack
modes:
- In order to obtain the closest possible correspondence
in length when using either standard or FLEX algorithms, the
computed length in Bend and Slack modes takes into consideration
the bend radius in order to obtain an even more realistic bundle
segment shape.
- Since the estimated shortest length (corresponding to
a slack value of 0) is not directly computed using the FLEX
algorithm, the user can enter a smaller input length when in
Length mode. A negative slack value will be displayed in the
Slack(%) box.
|
-
Click Route Definition and
route a bundle segment.
-
Click Apply in the Branch Definition dialog
box to compute the bend radius.
Computed Bend Radius
In FLEX mode, since the algorithm takes the
physical properties of the bundle segment (such as diameter, etc.)
as input, rather than purely mathematical parameters, CATIA
computes the effective minimum bend radius. The bend radius, which
is therefore no longer an input, is an attribute of the bundle
segment used for checks and can be accessed in knowledge tools.
Status lights show whether or not the computed bend
radius satisfies the minimum bend radius entered.

|
 |
Another build mode becomes available after you have routed a
bundle segment: Constrained length |
Build Mode - Constrained Length
The constrained length mode helps you minimize the
impact on manufacturing. For example, in this mode, modifying the
position of a support in the 3D view will not modify the flattened
view or the harness drawing.
This mode lets you keep the same bundle segment
length between points, branch points, supports and devices during
harness design and modification, when moving, replacing or deleting
a support, device or point. |
|
For example, move this support...

and the length of the bundle segment does not change:

|
 |
In this mode, you can set the percent
tolerance permitted between the initial and final bundle
segment length. For example, if you set this value to 1 and the
bundle segment is 100 mm long, then a final length of 101 mm will
be tolerated. Note: In Constrained Length mode, the default
accuracy is set to a very high value so that same bundle segment
length can be maintained. The value set for the balance slider is not
taken into account. |
|
A message informs you if the modification in bundle segment
length exceeds the tolerance and identifies for which branch this
is the case. |
 |
This build mode is recommended once you are well advanced in
your design because, in this mode, you cannot:
- add slack, supports, devices or branch points
- split bundle segments
- modify the length of a branch
- move a branch point
since these actions impact the length of the bundle
segment and CATIA cannot figure out how the user intends to modify
this length. |
-
Click Bundle Segment Definition and set bundle
segment parameters in the dialog box that opens.
The Bundle Segment
Definition dialog box opens. A Flexibility slider has been added in
the right-hand pane of the dialog box:

This slider lets you set a value between 1 and 5 to
define individual bundle segment stiffness. The lower the value,
the stiffer the bundle segment.
Important: This value is not taken into
account if wires and/or wire groups have been routed. In this case,
bundle segment stiffness is based on the properties of wires
and/wire groups. |
|
 |
Managing Slack Locally
You can add slack locally at
a specific location using the Local Slack command
.
However, the Ignore Slack option is not supported by the
FLEX algorithm and is not available in the Local Slack Management
dialog box. |
Updating an Existing
Harness
|
 |
This task shows you how to re-compute, using the FLEX algorithm,
harness bundle segments designed using the standard algorithm. |
 |
-
Set the
bundle segment computation mode to FLEX algorithm and adjust the
balance slider.
-
Select Tools > Recompute All Bundle Segments.
All bundle segments are highlighted in red in the geometry area. They
need to be updated.
-
Select Update
to rebuild bundle segments using the FLEX algorithm.
|
|
Notes:
- If no FLEX solution can be found, a message informs the user and the
standard algorithm is used.
- You can undo the recompute operation before or after the update.
- If you update branches with internal splices that were
designed in earlier releases, the branch shape may be slightly different
from that obtained previously because the FLEX algorithm takes internal
splices into account.
|